Alliance 2695, 2487, Oven and PC Integral Module

Make An Offer

Complete this form & send us your details.

Advertised price: £8,950

Instrument Details

Alliance 2695, 2487, Oven and PC Integral Module
£8,950
Model Alliance 2695, 2487, Oven and PC
Item no st3675
Manufacturer Waters
Available 17
Price £8,950
Warranty 6 month On-Site Warranty

Optional Extras

Upgrade Warranty
Installation

Description

Superb Waters Alliance 2695 system with oven, 2487 UV/VIS detector, PC, new TFT screen and printer!

Warranty Terms & Conditions For Used Equipment

hplc4sale.co.uk (Jaytee Biosciences Ltd) warranty all reconditioned instruments for a pre-agreed period. This period can be from 30 days to 1 year from the date of installation / delivery of the instrument. Generally newer equipment has a longer warranty than older equipment.

Additional warranty periods can be negotiated at the time of purchase if required.

The list below outlines the items covered by our warranty:

Parts Included In Warranty

  • Electronic Assemblies – e.g. PCB’s, Transducers, Interface Cards
  • Mechanical Assemblies – e.g. Pump Drive assemblies, XYZ Transport Systems
  • Power Supplies – e.g Low and High Voltage Supplies, Lamp Supplies, Cases, Metalwork and Enclosures.
  • Major assemblies – PCB’s, Power Supplies, and Displays etc covered for warranty term.

Typical Parts NOT Included In Warranty (Integral Modules)

  • Wetted Path Components
  • Software Updates
  • Tubing and Fittings
  • Capillaries
  • Consumable Parts
  • Tools
Loading

Are you an academic organisation?

This Alliance 2695, 2487, Oven and PC Integral Module applies for a University discount - enquire for full details...
Download specification

Waters Alliance 2695 Spec

This Waters Alliance 2695 Separations Module consists of a quarternary pump, degasser and a variable volume autosampler, capable of injecting from 5 x 24 2ml vials.

The four solvent in-line degasser offers a high efficiency alternative to helium sparging for the removal of dissolved gases from HPLC mobile phases.

Alliance (Year 2000)

Designed  for a wide   variety of applications, this reliable tool is a common work-horse in   most analytical and contract labs.  Built to meet labs rigorous   requirements or routine analysis,  suited to Pharmaceutical, Food Safety, R&D, Chemistry, Environmental or   Quality Control labs. Featuring a large, easy-to-use   LCD interface, take advantage of the quick autostart and   optimize your methods with a simple push of a button.  Manage up to   120 industry standard vials with the built in autosampler



*Sample chiller available for this Alliance - add £2000 - enquire for details.

Solvent Management
Number of Solvents 1 to 4
Solvent conditioningVacuum degas, two operating modes, four chambers, < 5000µL internal volume per chamber 0.000 to 10.000 mL/min (0.050 to 5.00 mL/min typical) in 0.001 mL/min increments
Compressibility compensationAutomatic and continous
System delay volume < 650µL, independent of backpressure at 1mL/min
Plunger seal washIntegral, active, programmable 
Gradient profiles 11 gradient curves including linear, step (2), concave (4), and convex (4)  
Dry prime/wet primeAutomatic front panel control, SystemPrep function for automatic solvent(s) purge 
Flow ramping Time (0.01 to 30.00 min in 0.01 min increments) to reach maximum flow rates
Maximum operating pressure5000 psi (345 bar) (0.010 to 3.000 mL/min) programmable upper and lower limits 
Composition range 0.0% to 100.0%, in 0.1% increments
Composition accuracy ±0.5% absolute, independent of backpressure (proportioning valve pair test, [degassed methanol: methanol/propylparaben, 2.0mL/min, 254nm]) 
Composition precision≤0.15% RSD or ≤0.02 min SD, whichever is greater, based on retention time (degassed methanol: water 60:40 dial-a-mix, 1.00mL/min, six replicates, phenone mix, 254nm) 
Flow precision≤0.075% RSD or ≤0.02 min SD, six replicates, based on retention time or volumetric measures (0.200 to 5.000 mL/min), isocratic premix 
Flow rate range 0.000 to 10.000 mL/min (0.050 to 5.000 mL/min typical) in 0.001mL/min increments 
Flow accuracy ±1% or 100µL/min whichever is greater, 0.200 to 5.000 mL/min (degassed methanol, at 600 psi backpressure) 

Column Heater

The column heater   provides accurate temperature control which enhances chromatographic results by creating a consistent separation environment for method reproducibility. It has a capacity of two columns (8mm ID mx, 30cm length max). Heats up to 60°C, programmable in 1 °C increments.

2487 UV/Vis Detector

The 2487 detector is a 2 channel, tunable ultraviolet/visible (UV/Vis) detector that operates in single or dual wavelength mode, allowing spectrum scanning using a flow cell or a cuvette, providing RatioPlot and MaxPlot functions.
 
Single Wavelength Mode
Single wavelength is the default mode of operation for the 2487, supporting monitoring of a single wavelength from 190nm to 700nm, settable in 1nm increments on Channel A.

Dual Wavelength Mode
In dual wavelength mode, the detector monitors on Channel A and Channel B. The sampling frequency is reduced from 10Hz to 1Hz, limiting use of this mode to more standard chromatography, where peaks span at least 20 seconds to enable full characterisation of a peak.

Features
Stand-alone programmability - Stores up to 10 user defined programs (or methods) consisting of up to 16 programmable timed  events and 2 threshold events each.

Integral erbium calibration reference - ensures wavelength accuracy

Automatic second order filter - Automatically enganged for wavelengths 370nm and greater and removed for wavelengths 369nm or less.

Spectrum scan and storage - supports spectrum scan, display, subtraction, storage and playback, in addition to standard tunable absorbance and UV/Vis functionality.

Cuvette qualification - facilities qualification of the detector by insertion of a standard in a cuvette without breaking any fluidic connections.

Cuvette sample analysis - allows the spectrum of any sample placed in the cuvette to be recorded.

Method editing and storage - supports basic method programming, storage and retrieval from the front panel

Full diagnostic capability - supports built in diagnostic tools to optimize functionality and performance.

Backward compatibility - operates as a 486 detector with Millenium Chomatography manager version 2.1n and lower, PowerLine, ExpertEase and other Waters products connected via the LAC/E interface using the IEEE-488 bus.

Specification

Wavelength range: 190nm to 700nm
Bandwidth: 5nm
Accuracy: ± 1nm
Repeatability: ±0.10nm
Sensitivity setting range: 0.0001 AUFS to 4.0000 AUFS
Lamp Source: Deuterium arc lamp
Flow cell: TaperSlit Flow Cell Design
Pressure limit: 1000psi / 70bar
Materials: 316 stainless steel, fused silica, Teflon.
Operating temperature: 4°C to 40°C
Operating humidity: 20% to 80%, noncondensing
Line frequency: 50Hz to 60Hz
Dimensions: 208mm(H) x 503mm (L) x 284mm (W)
Weight: 9.3 kg

 

 

Operating Voltage for the system: 230 Volts AC.

This item is in excellent condition, comes with full OQ documentation and is superb value - please contact us below for a quotation.

Installation option available:

EnquireMake An Offer

Interest in st3675 Waters Alliance 2695, 2487, Oven and PC Integral Module

Please enter your details below, or phone +44(0)1227 465333.

Enquire

Interested in renting this instrument:

Please add these 2 numbers:
MCN         C5D      
L H    Y    O     IER
R 8   PSG   WR1      
7 S    X      A   96X
38K         LSK      

Related Products

Also

  • +44 (0) 1227 265333
  • sales@jaytee.com