Waters H-Class Acquity Binary UPLC System

Make An Offer

Complete this form & send us your details.

System Details

Waters H-Class Acquity Binary UPLC System
CALL

Item H-Class
Manufacturer Waters
Price Please Call
Warranty 12 month On-Site Warranty (UK)

Optional Extras

Installation

The Acquity system comes complete with OQ Certification.

  • The quaternary pump has been tested for faulty parts such as seals and check valves
  • The detector has been tested for wavelength accuracy
  • The sample manager has been tested for area of reproducibility

Warranty Terms & Conditions For Used Equipment

Note: Our warranty terms quoted for this system apply to mainland UK customers. For clients outside of this locale, please enquire at point of sale.

hplc4sale.co.uk (Jaytee Biosciences Ltd) warranty all reconditioned instruments for a pre-agreed period. This period can be from 30 days to 1 year from the date of installation / delivery of the instrument. Generally newer equipment has a longer warranty than older equipment.

Additional warranty periods can be negotiated at the time of purchase if required.

The list below outlines the items covered by our warranty:

Parts Included In Warranty

  • Electronic Assemblies – e.g. PCB’s, Transducers, Interface Cards
  • Mechanical Assemblies – e.g. Pump Drive assemblies, XYZ Transport Systems
  • Power Supplies – e.g Low and High Voltage Supplies, Lamp Supplies, Cases, Metalwork and Enclosures.
  • Major assemblies – PCB’s, Power Supplies, and Displays etc covered for warranty term.

Typical Parts NOT Included In Warranty

HPLC Pumps

  • Plungers
  • Plunger Seals
  • Check Valves
  • Check Valve Cartridges
  • Frits
  • Purge Valve
  • Solvent Filters
  • Gaskets
  • Wash Seals
  • Degasser fluid parts
  • Gradient Valves

HPLC Detectors

  • Cell Assemblies
  • Cell Rebuild Kit
  • Lamp Assembly

Autosampler

  • Needle
  • Needle Seat
  • Needle Seat Holder
  • Rotor Seal
  • Stator Face
  • Isolation Seal
  • Plunger
  • Plunger Seals
  • Syringes

GC Autosampler

  • Syringe
  • Liner
  • Septa
  • Jet
  • Ferrules
  • Column Fittings
  • Gas Filters

Gas Chromatograph

  • Syringe
  • Liner
  • Septa
  • Jet
  • Ferrules
  • Column Fittings
  • Gas Filters

Misceallenous

  • Wetted Path Components
  • Software Updates
  • Tubing and Fittings
  • Capillaries
  • Consumable Parts
  • Tools
Download H-Class Acquity OQ and Reproducibility data

Acquity Binary UPLC system (H-Class) from Waters. This fantastic system delivers the flexibility of quaternary solvent blending with the advanced performance of UPLC® separations. The systems holistic design is targeted for routine analysis and method development use and is perfectly suited for running both HPLC and UPLC applications while still delivering the improved resolution and sensitivity of UPLC separations. Complete with an OQ certification - see photos.

Includes fully reconditioned and serviced:

  • Waters Acquity H-Class Quaternary Solvent Manager (QSM)
  • Waters Acquity H-Class Sample Manager Flow Through Needle (SM-FTN)
  • Waters Acquity H-Class Diode Array Detector (PDA)
  • Waters Acquity H-Class Column Manager (CM-A)
  • Bottle Manager

Optional extras (enquire for price):

  1. Acquity TUV (UV Detector)
  2. Column Organiser
  3. Column Manager AUX

We can supply software, PC printer and installation - please call +44(0)1227 265333 for a full quotation. Contact Us

H-Class System Specification

Dwell volume (total system): <400 µL (includes standard 100 µL mixer)

Integrated leak management: Leak sensors, as standard, and safe leak handling.

Quantum synchronization: Injection synchronization between pump and sample manager enhances retention time reproducibility.

pH range: 2 to 12

Unattended operation: Leak sensors and safe leak handling, full 96-hour diagnostic data display through console software.

Cycle time: <30 s inject-to-inject

Settable flow rate range: 0.010 to 2.000 mL/min, in 0.001 mL increments (firmware version 1.5x and earlier).

Maximum operating pressure: 15,000 psi up to 1.0 mL/min,7800 psi up to 2.2 mL/min (firmware version 1.6x and later).

QSM Specification

Number of solvents: Blend up to four solvents in any combination (standard). Expanded solvent choices with optional six-port solvent select valve.

Solvent degassing: Integrated vacuum degassing, four chambers. One additional chamber for the SM-FTN purge solvent.

Solvent blending: Automated, on-line pH, ionic strength, and organic modifier blending from pure solvents with Auto•Blend Plus™ Technology.

Gradient formation: Low-pressure mixing, quaternary gradient.

Flow accuracy: ±1.0% at 0.5 to 2.0 mL/min using 100% A (with i2 Valve). Back pressure 600 to 1000 psi with degassed H20.

SM-FTN Specification

Injection volume range: 0.1 to 10.0 µL as standard in 0.1 µL increments. Up to 1000.0 µL with optional extension loops.

Accuracy (aspiration): ±0.2 µL, measured by fluid weight removed from vial with 10.0 µL injections averaged over 20 injections using standard 100 µL syringe.

Linearity: >0.999 (standard needle) caffeine 0.030 mg/mL, ACN/H2O (10:90), isocratic 0.6 mL/min, 0.2 to 10.0 µL, 1 to 70% needle volume.

Sample compartment: 4.0 to 40.0 °C, settable in 0.1 °C increments

PDA eλ Specification

Wavelength range 1: 190 to 800 nm

Wavelength accuracy: ±1 nm

Linearity range: Deviation at 2.0 AU ≤ 5%, propylparaben, at 257 nm

Data acquisition: Up to 80 Hz.

Pressure limit: 1000 psi

Flow cell design: Light-guiding UPLC intelligent technology flow cell.

CM-A Specification

Column capacity: Two columns, as standard (maximum length of 150 mm with filter or guard column) or four columns (maximum length of 50 mm) can be supported with optional tubing kit, up to 4.6 mm internal diameter (I.D.).

Switching valves: Two nine-port, eight-position valves providing programmable, automatic, random access switching, waste and bypass positions for rapid solvent changeover

Column compartment temperature range: 4.0 to 90.0 °C, settable in 0.1 °C increments. Two independent heat/cool zones per module, up to six zones in stacked configuration.

Column compartment temperature accuracy: ±0.5 °C at sensor.

Column compartment temperature stability: ±0.3 °C at sensor.

Solvent conditioning: Active pre-heating as standard.

Column tracking: eCord™ Technology column information management tracks and archives column usage history.

2D support: Optional

View Waters System Specification | View Waters PDA Specification

View all Acquity Systems

Note: Licenses for Waters software products are not transferable. Any customer who purchases Waters products are advised that in order to hold a valid license to use the Waters software, they must purchase a license and appropriate Application Manager directly from Waters.
Installation option available. Please note that all prices quoted are exclusive of UK VAT.

EnquireMake An Offer

Interest in System 107 - Waters H-Class Acquity Binary UPLC

Please enter your details.

Enquire

Interested in renting this instrument:


Please add these 2 numbers:
LP1         IOY      
K 7    B    5 E   5P9
2TN   829   B W      
I D    E    G 4   3XI
F1K         59R      
I wish to be contacted by Jaytee Biosciences
Ltd regarding this enquiry.
I am happy to be contacted in future by Jaytee Biosciences Ltd in related matters.

Also

  • +44 (0) 1227 265333
  • sales@jaytee.com